Description
This listing consists of 4 pcs 150AH 12V batteries
At last, a truly safe and effective battery for the 1 to 150+ kWh storage requirements for solar installations.
This listing is for 4 x 12V 150ah units, each weighing 98.11 lbs
Call for quotes to CAN and MEX,
Islands and Territories( PR, HI, AK VI), we can ship to your local forwarder
These are shipped on pallets to you, available in quantities of 4 pcs upwards. Maximum of 2000lbs per pallet shipping weight (30 pcs per pallet),
1 pc can technically be shipped via Fedex Ground,
- Advanced technology for the solar age. Completely recyclable
- Lower cost compared to Li-Ion
- Similar Lifespan to Li-ion 6 to 15 yrs
- Long lasting, fast charging capability, low internal resistance (see chart below independent analysis 6 to 15 yrs)
- No Off-gassing, completely inert (used indoors in non ventilated spaces)
- Capable of 100% depth of discharge, no memory effect
- No thermal runaway, like Lithium based technologies
- Non Combustible, Non Toxic, electrolyte is non corrosive,
- Self Balancing – No BMS (battery Management) or Balancing required
- No Equalization voltage required
- Direct Drop in replacement for Flooded or Lead Acid Batteries (also compatible with most Lithium-ion based charge voltages)
- No Pre Charging resistor required to connect to inverter- no BMS to tripping (resistor is still recommended to avoid a connection spark)
- Huge Surge currents, similar to High CCA (Cold Cranking Amps) for Lead Acid Batteries
- Used in starter and deep cycle applications
- Wide temperature range from -40F to 158F
Specifications
Nominal Voltage 12V/24V/48V
Nominal Capacity (10HR) 150AH (1.8kWH)
Dimensions
Length 19.02 inches
Width 16.69 inches
Container Height 9.45 inches
Approx Weight 98.11 lbs
Terminal M8
Container Material ABS
Capacity
150AH / 10.0A (10hr, 1.80V / cell, 25℃ / 77℉)
Cranking Amps -40°C (-40°F) ⌁ +70°C (+158°F) 1000 – 1500
Reserve Capacity (@ 25A) 185 Minutes
Reserve Capacity (@ 75A) 47 Minutes
Max. Discharge Current 800A (8.0C) for 10 seconds
Internal Resistance Approx 2mΩ-5mΩ
Operating Temp. Range
Discharge: -40℃⌁70℃ (-40℉⌁158℉)
Charge: -20℃⌁50℃ (-20℉⌁122℉)
Storage: -20℃⌁50℃ (-20℉⌁122℉)
Depth of Discharge (DOD)
Max. With Immediate Recharge 100%
Recommended Max. 90%
Recommended for Extended Battery Life 50%
Charge
Cycle Use
Float Use
Regular Charge (recommended)
Quick Charge
Fast Charge
Ultra-Fast Charge
Recommended Charge Current (String)
Maximum Charge Current (String)
Self Discharge
2.45V/cell (Top Recommended
Charge Voltage)
2.27V/cell @ 0.6C
10A (0.1C) (10.5 Hours)
30A (0.3C) (3.2 Hours)
100A (1.0C) (1.1 Hours)
300A (3.0C) (25 Minutes)
10A (0.1C)
300A (3.0C)
self discharge
15⌁20% After 12 Months over 2 years @ 25C(77F)
Warranty: 5 years.
Warranty applies to systems which have a battery capacity of at least 2 x daily consumption.
example, if daily use is 12kwh, a minimum requirement of 24kwh capacity is expected
Through experience, we find that ANY battery chemistry, when cycled 100% every day with high charge and discharge currents has a limited lifespan, some LiFEPo4 batteries make it to about 3 months when worked hard