Description
Supported By Watts247 / Current Connected
We are trying to help customers get prepared for what is shortly to come, if you don’t know what I mean, then this isn’t for you. (One day everything will STOP, yes the signs all all over, and its happening faster than anyone can imagine)
- 48 Volt (51.2 Nominal) 100Ah, 5.12 kWh
- 20 Year Typical Lifespan & 10 Year Warranty
- Cells rated for 80% Capacity after 4000 Cycles, 100% DOD @1C Rate
- Typical capacity at 80% DOD @.5C Rate is over 7000 Cycles
- Maintenance Free
- Built-In Smart Battery Management System (BMS)
- 5 Temperature sensors, protected from low and high temperatures
- Pre-Charge Circuit to Prevent BMS Damage
- Detachable cover, user serviceable BMS and cells
- RS485 & CANBus communication, works with many inverters.
- Be sure to select the proper communications cables.
- Rack Mountable for quick and easy installation
- Well-written English instruction manual & documentation here.
SOK Owner / Operator Manual: Chapter 1 – UL Certification Information
About the certification:
The SK48v100 has been tested by Intertek Laboratories and has been tested to conform to UL 1973 standards. The draft testing report is available here and a final version of this report will be posted soon (Approx. Mid October).
Why is UL listing important?
Local AHJ’s (authority having jurisdiction) have began adopting 2017 NEC that requires batteries and energy storage system to be listed. This excludes non-listed packs from being used in a system that is code-compliant (permitted). Now that the SK48v100 is listed to UL standards, it can be used in a system that is permitted, inspected and insured.
Often times insurance providers will deny a claim for damage if an unlisted system is involved in a claim, even if the unlisted system is not the cause of such claims.
About the packs already shipped and installed:
The certification to UL1973 standards utilizes the same hardware that the SK48v100 has used since its initial conception, therefore, existing equipment conforms to the requirements for UL1973. If you have these initial packs that do not bear the “Conforms to UL1973 standards” label, then you may contact us for these labels.
GROWATT Communications .
https://www.currentconnected.com/sk48v100/manual-4-6/
Specifications
Electrical Properties | |
---|---|
Model | SK48v100 |
Nominal Voltage | 51.2 (48v Range) |
Nominal Capacity | 100Ah |
Run Time at 20A Load (~1000w) | 300 Minutes |
Energy | 5120Wh |
Self Discharge | < 3% per month |
Max Batteries in Series | 1 |
Max Batteries in Parallel (with BMS communication) | 15* |
Maximum Terminal Feedthrough Current | 350 Amps |
Discharge Performance | |
Max Continuous Discharge Current | 100A (1C) |
Peak Discharge Current | 125A (3 Seconds, automatic shutdown) |
Short Circuit Protection | 300a, 200µs |
BMS Low-Voltage Disconnect | 46v |
BMS Low-Voltage recover | 48v |
Charge Performance | |
Recommended Charge Current | 0~63A |
Maximum Charge Current (Continuous) | 100A |
Recommended Charge (Absorption) Voltage | 57.6 |
BMS Cell Protection Voltage | 3.7v |
BMS Pack Protection Voltage | >58.2v |
Temperature Performance | |
Discharge Temperature | -4°F – 140°F |
Charge Temperature | 32°F – 113°F |
Storage Temperature | 23°F – 95°F |
Low Temperature Charge Protection | Yes |
Internal Temperature Sensors | 4 Cell Sensors, 1 BMS Sensor, 1 Ambient Air Sensor |
Physical Properties | |
Case Material | Powder-Coated Steel |
Rack Mountable | Yes, 4U |
Dimensions | Width: 17.5in (Without ears – Fits standard 18″ rack with ears installed)
Height: 7in (4 rack units) Depth: 18in + 1 1/4″ for handles / terminals |
Unit Weight | 99.2Lbs |
Weather Rating | IP20 |
Third Party Testing | Pack UL1973 Testing Passed – Certified packs anticipated to ship from Current Connected September 2022
UL9540 |
Shipping Classification | UN3480, Class 9, MSDS |